Violations PASS
- WARNING Splitter 'spl-1x8-BG-01' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-02' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-03' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-04' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-05' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-06' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-07' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-08' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-09' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-10' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-11' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-12' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-13' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-14' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-15' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Splitter 'spl-1x8-BG-16' (1x8) has only 1 spare port(s) (Lumos planning standard: ~4 spare per 1x8).
- WARNING Bend at hh-068: both adjacent segments exceed 150ft (275ft, 275ft)
- WARNING Bend at hh-069: both adjacent segments exceed 150ft (284ft, 284ft)
- WARNING Bend at hh-012: both adjacent segments exceed 150ft (431ft, 464ft)
- WARNING Bend at hh-039: both adjacent segments exceed 150ft (153ft, 287ft)
- WARNING Bend at hh-052: both adjacent segments exceed 150ft (218ft, 235ft)
- WARNING Bend at hh-056: both adjacent segments exceed 150ft (235ft, 395ft)
- WARNING Bend at hh-053: both adjacent segments exceed 150ft (265ft, 223ft)
- WARNING Bend at hh-055: both adjacent segments exceed 150ft (185ft, 302ft)
- WARNING Bend at hh-054: both adjacent segments exceed 150ft (235ft, 328ft)
- WARNING Bend at hh-036: both adjacent segments exceed 150ft (333ft, 354ft)
- WARNING Bend at hh-033: both adjacent segments exceed 150ft (354ft, 348ft)
- WARNING Bend at hh-018: both adjacent segments exceed 150ft (446ft, 433ft)
- WARNING Bend at hh-070: both adjacent segments exceed 150ft (260ft, 260ft)
- WARNING Bend at hh-071: both adjacent segments exceed 150ft (363ft, 363ft)
- WARNING Handhole hh-011 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-016 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-024 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-025 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-030 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-042 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-043 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-045 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-047 is a three-way splice but is SPLT (recommend SM or MED)
- WARNING Handhole hh-057 is a three-way splice but is SPLT (recommend SM or MED)